Drinking water heating systems

Depending on the application, you can choose from a wide range of drinking water circuits. For both primary and secondary connected DHW heating systems, we offer storage tank heating, storage tank charging and flow-through systems.

We offer a comprehensive range of systems and accessories for domestic hot water heating. Our storage tank heating, storage tank charging and flow-through systems have been developed both for systems with and without existing differential pressure. Furthermore, there are different control elements, so you will find the right water heating system for your application. What all systems have in common is their extremely compact design and high quality – so that you can use and enjoy your water without any worries.

Drinking water heating systems

ewers Trinkwassererwärmungssysteme - Trinkwassererwärmung - Trinkwasserstation

Types of heating drinking water

  • Accumulator heating systems (accumulators with internal coiled tubing)

  • Storage charging systems (stratified charging storage)

  • Flow systems secondary with buffer tank

  • Primary connected flow systems

  • Outputs
    10 kW to 400 kW in standard

ewers Trinkwassererwärmungssysteme - Trinkwassererwärmung - Trinkwasserstation
Drinking water heating station

Flow system with plate heat exchanger

ewers drinking water heating systems - Drinking water heating - Drinking water station
Drinking water heating station

Flow system with plate heat exchanger

ewers Trinkwassererwärmungssysteme - Trinkwassererwärmung - Trinkwasserstation
Drinking water heating station

Flow system with coaxial heat exchanger

ewers Trinkwassererwärmungssysteme - Trinkwassererwärmung - Trinkwasserstation
Drinking water heating station

Two-stage storage charging system

Trinkwasser-Erwärmungssysteme in verschiedenen Ausführungen
ewers Trinkwassererwärmungssysteme - Speichererwärmungssystem

Hydraulic illustration of a plant with storage heating system

STORAGE HEATING SYSTEMS

In the case of storage tank heating via a coiled tubing storage tank, the drinking water is heated directly in the storage tank by the internal coiled tubing/pipe coils. These are located in the lower area of the storage tank, so the heating takes place from bottom to top. The coils in the storage tank act as heat exchangers. The heating time depends on the size of the storage tank, the heat output and the settings made.

The spiral-shaped pipe coils are made of corrosion-resistant materials such as stainless steel, enameled steel or copper. For this drinking water heating system we offer you different storage tanks according to your needs.

  • Indirectly heated floor-standing storage tanks with permanently welded-in smooth-tube heat exchanger

  • For combination with all modern heating systems
  • For local and district heating

STORAGE CHARGING SYSTEMS

Storage charging systems – whether direct or indirect – heat domestic and drinking water. To guarantee a long corrosion-free service life, we manufacture them from high-quality materials such as gunmetal and stainless steel. Depending on requirements, our storage tank charging systems are controlled either thermally, thermally-hydraulically, electronically or with a jet pump.

  • Priority operation (without admixture)

  • Simultaneous operation (with admixture)

  • Tertiary circuit

ewers Trinkwassererwärmungssysteme - Speicherladesystem

Hydraulic illustration of a plant with storage tank charging system

ewers Trinkwassererwärmungssysteme - Durchflusssystem

Hydraulic illustration of a plant with flow system

FLOW SYSTEMS

Ensure 100% efficiency. Plus comfort.

With ewers flow-through systems, the water is only heated when it is needed. This makes it extremely hygienic. Both the direct and indirect variants are ideal for installing even decentralized and close to the tap. This adds convenience, because the hot water flows in the shortest possible time. Choose between thermal, thermal-hydraulic, electronic or jet pump for control.

Flow systems for heating medium circuits without differential pressure

  • Controlled via thermal three-way mixer

  • Controlled via thermal bypass

  • Electronically controlled

Flow systems for heating medium circuits with differential pressure

  • Thermally-hydraulically controlled

  • Electronically controlled

SPEICHER-ERWÄRMUNGSSYSTEME

Bei der Speichererwärmung über einen Rohrwendelspeicher wird das Trinkwasser direkt im Speicher von den innen liegenden Rohrwendel/Rohrschlangen erhitzt. Diese befinden sich im unteren Bereich des Speichers, die Erwärmung findet also von unten nach oben statt. Die Rohrschlangen im Speicher fungieren hierbei als Wärmetauscher. Die Aufheizzeit richtet sich nach Speichergröße, Wärmeleistung und den vorgenommenen Einstellungen.

Die spiralförmigen Rohrwendel bestehen aus korrosionsbeständigen Werkstoffen wie z. B. Edelstahl, emailliertem Stahl oder Kupfer. Für dieses Trinkwassererwärmungssystem bieten wir Ihnen unterschiedliche Speicher ganz nach Ihrem Bedarf.

  • indirekt beheizte Standspeicher mit fest eingeschweißtem Glattrohrwärmetauscher

  • zur Kombination mit allen modernen Heizungsanlagen

  • Für die Nah- und Fernwärme

ewers Trinkwassererwärmungssysteme - Speichererwärmungssystem

Hydraulische Abbildung einer Anlage mit Speicher-Erwärmungssystem

SPEICHERLADESYSTEME

Speicherladesysteme – ob direkt oder indirekt – erwärmen Brauch- und Trinkwasser. Um eine lange korrosionsfreie Lebensdauer zu garantieren, fertigen wir sie aus hochwertigen Werkstoffen wie Rotguss und Edelstahl. Unsere Speicherladesysteme werden je nach Anforderung wahlweise thermisch, thermisch-hydraulisch, elektronisch oder mit Strahlpumpe geregelt.

  • Vorrangschaltung (ohne Beimischung)

  • Gleichzeitigkeitsbetrieb (mit Beimischung)

  • Tertiärschaltung

ewers Trinkwassererwärmungssysteme - Speicherladesystem

Hydraulische Abbildung einer Anlage mit Speicherladesystem

DURCHFLUSSSYSTEME

Sichern Sie sich 100% Effizienz. Plus Komfort.

Mit ewers-Durchflusssystemen wird das Wasser erst dann erwärmt, wenn es gebraucht wird. So ist es äußerst hygienisch. Sowohl die direkte als auch die indirekte Variante eignen sich hervorragend, um sie auch dezentral und nah an der Zapfstelle zu installieren. Das bringt ein Plus an Komfort, denn das warme Wasser fließt in kürzester Zeit. Wählen Sie bei der Regelung zwischen thermisch, thermisch-hydraulisch, elektronisch oder Strahlpumpe.

Durchflusssysteme für Heizmittelkreise ohne Differenzdruck

  • Geregelt über thermischen Dreiwegemischer

  • Geregelt über thermischen Bypass

  • Elektronisch geregelt

 

Durchflusssysteme für Heizmittelkreise mit Differenzdruck

  • Thermisch-hydraulisch geregelt

  • Elektronisch geregelt

ewers Trinkwassererwärmungssysteme - Durchflusssystem

Hydraulische Abbildung einer Anlage mit Durchflusssystem

Sie möchten noch mehr
über ewers Wärmesysteme
wissen?
Übersicht Wärmesysteme
Trinkwasser-Erwärmungssysteme
WOHNUNGSSTATIONEN
MESS- & REGELMODULE
SPEICHERTECHNIK & ZUBEHÖR